Dansach Electrical Supplies

AIEWMember Electrical Product Catalogue Issue 18 SPECIAL SELECTION A rigid structure which supports and feeds lighting, in single phase or three phase. Conforms to BS EN 60439-2 Conductors are protected by an auto-extinguishing sheath. Body is hot dip galvanised steel to BS EN 10142, which forms the protective earth. IP55 (according to BS EN 60529) Trunking lengths Lengths with 2 or 3 tap-off outlets (spaced every 1.0m) are supplied with outlet covers fitted. Lengths with 6 tap-off outlets (spaced every 0.5m) are supplied with 3 tap-off covers fitted. Without outlets Feeder lengths. A tap-off point is only possible on the junction between 2 lengths Trunking lengths – 3 m For vertical runs or riser applications. Special lengths between 400mm and 3m are available upon request. IP40 protection when installed with outlets facing up. IP52 protection when installed edgeways. IP55 protection when using tap-off outlet covers and appropriate accessories. Flame retardant in compliance with IEC 60332-3. Fully compliant with BS EN 60439-2. Rated currents are at an average ambient temperature of 40 º C (over and above the required standard of 35 º C). Light Duty LB Single Sided Lighting Busbar Conforms to BS EN 60439-2. Casing manufactured from Senzimir quality galvanised steel suitable for use as a protective earth. IP40 as standard, increasing to IP55 with use of appropriate accessories. 63A Cat. Nos Length (m) Outlet points Weight (kg) 51530101 3 3 + 3 7.890 51530116 2 2 + 2 5.260 51530115 1.5 1 + 1 3.945 51530114 1 1 + 1 2.630 51530112 < 1.5 – – 51530113 > 1.5 – – Trunking lengths Tap-off outlets are spaced every 1.0 m on both sides and are fitted with shutters to prevent accidental contact with live parts. Expansion joints are not required. Available in 100A and 160A with Fire Barrier / with Thrust unit Low and medium power 63/100/160A MS Double Sided Busbar Medium power 160 - 1000A MR Medium Rating Busbar Complete range available ask for details of accessories and components or for a competitive quote 63A with fire barrier For vertical runs or riser applications exceeding 20m Lengths are fitted with a fire barrier and are used to pass through fire-resistant walls In accordance with DIN 4102-9 and EN 1366-3 63 A with thrust unit For vertical runs or riser applications exceeding 20m 51530131 3 3 + 3 7.990 51530141 3 3 + 3 7.890 Aluminium Copper Rating (A) Weight (kg) Copper Aluminium 50400101 160 19.9 – 50400102 55400102 250 20.9 25.7 50400103 55400103 315 22.8 28.1 50400104 55400104 400 33.8 36.9 50400108 500 37.5 – 50400105 55400105 630 41.7 56.0 50400106 55400106 800 44.3 72.1 55400107 1000 – 83.7 50400251 160 19.9 – 50400252 55400252 250 20.9 25.7 50400253 55400253 315 22.8 28.1 50400254 55400254 400 33.8 36.9 50400258 500 37.5 – 50400255 55400255 630 41.7 56.0 50400256 55400256 800 44.3 72.1 55400257 1000 – 83.7 Aluminium Copper Rating (A) Weight (kg) Copper Aluminium 50400241 160 19.9 – 50400242 55400242 250 20.9 25.7 50400243 55400243 315 22.8 28.1 50400244 55400244 400 33.8 36.9 50400248 500 37.5 – 50400245 55400245 630 41.7 56.1 50400246 55400246 800 44.3 72.1 55400247 1000 – 83.7 With 3 + 3 outlets Tap-off outlets are spaced every 1m on both sides (6 positions/3m length) With 5 outlets on one side Suitable for rising mains

RkJQdWJsaXNoZXIy MjQwMjM=